Standard FD60 Intumescent Protection - ARRONE
| Arrone | Doorpac | Flamebreak | Halspan | Vicaima | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Strebord FD60 | FD60 Blank | Prima FD60 | Optima FD60 | FD60 Prima | |||||||||
| Reference | Lock Type | Machining Parameter | Lock Certificate No | CF5229 | CF5261 | CF436 | CF535 | CF454 | |||||
| AR910R | Sashlock | PAR075 | CF530 | 2mm Interdens Intumescent Sheet Material To Fully Wrap Lock Case & Below Forend & Keep | NOT PERMITTED - Locks Exceed Maximum Certificated Dimensions | 1mm Thickness Of Interdens Mono Ammonium Phospahte Intumescent Sheet Material Around The Lock Case & Behind The Forend & Strike Plate. Additionally, The Perimeter Intumescent Fire Seal Within The Frame/Door Edge Shall By-pass The Strike Plate Or Forend By A Minimum Of 8mm Wide On Each Side |
1mm Thickness Of Interdens Mono Ammonium Phospahte Intumescent Sheet Material Around The Lock Case & Behind The Forend & Strike Plate. Additionally, The Perimeter Intumescent Fire Seal Within The Frame/Door Edge Shall By-pass The Strike Plate Or Forend By A Minimum Of 8mm Wide On Each Side |
||||||
| AR915R | Escape Sashlock | PAR0043 | |||||||||||