Door Information - Doorpac

Approved Door Configurations
Doorpac Valid To Single Acting Single Doors Single Acting Double Doors Double Acting Doors Quick2Fit Concealed Closers Minimum Secondary
Door Width
Standard Hinge
Intumescents
Thermal Transmittance
(U) Value (W/m2K)
LSASD ULSASD LSADD ULSADD DASD DADD
Strebord FD30 CF5228 01/11/2026 300mm (From Falcon FoA) 1mm Interdens Below Each Blade
In Leaf & Frame
2.0
Strebord FD60 CF5229 02/11/2026 1 300mm (From Falcon FoA) 1mm Interdens Below Each Blade
In Leaf & Frame
1.8
1. FD60 Double Acting Door Doors Unlatched Only - No Hardware Permitted To Meeting Edge
Minimum Leaf Height = 1200mm
- See Door Certificates & Concealed Closer Pages For Further Information
NOTE: Quick2Fit Architrave Cannot Be Specified To The Pull Face Of Doorsets Fitted With Concealed Closers

LSASD: Latched Single Acting Single Door ULSASD: Unlatched Single Acting Single Door LSADD: Latched Single Acting Double Door ULSADD: Unlatched Single Acting Double Door DASD: Double Acting Single Door DADD: Double Acting Double Door
Maxmimum Permitted Aperture Dimensions
Manufacturer Configuration Max Height
(mm)
Max Width
(mm)
Max Area
(m2)
Multiple
Apertures
Min Door
Edge Margin
(mm)
Min Core
Material
Between
Apertures
(mm)
Strebord FD30 CF5228 Latched & Unlatched 2085
(at 725 wide)
822
(at 1840 high)
1.51 100 100
Latched Only 2412
(at 1220 wide)
1220
(at 2412 high)
2.94 100 100
Strebord FD60 CF5229 Latched & Unlatched 2201
(at 510 wide)
604
(at 1860 high)
1.12 120 120
See Door Certificates For More Information